Vivace RF Tips: A Guide to 36-Pin Insulated and Non-Insulated Cartridges
Vivace RF tips are replaceable microneedle cartridges used with the appropriate Vivace radiofrequency microneedling equipment. When ordering replacement tips, clinics need to identify the needle configuration, insulation type and supported handpiece.
Descriptions such as “Vivace blue tips,” “Vivace red cartridges” or “36-pin RF needles” can help customers search, but they do not provide a complete purchasing specification.
This guide explains the main cartridge terminology, the difference between insulated and non-insulated needles, and the checks needed before purchasing. Clinical selection and operation must follow the current manufacturer instructions for the exact equipment.
What Are Vivace RF Cartridges?
A Vivace cartridge contains the microneedle electrodes used with the system’s handpiece. It is a consumable component, separate from the handpiece and main device.
SHENB describes Vivace as a medical device for tissue coagulation using high-frequency currents. Its product page identifies two needle types, selectable 1 MHz and 2 MHz RF options, adjustable depth and red or blue LED modes. shenb.com
Suppliers commonly describe the consumables as:
- Vivace RF tips.
- Vivace cartridges.
- Vivace microneedling tips.
- Vivace replacement needle sets.
- Vivace 36-pin cartridges.
- Vivace insulated tips.
- Vivace non-insulated tips.
These terms identify a product category. Exact compatibility requires the complete cartridge reference and equipment information.
Vivace 36-Pin Needle Cartridges
Published Vivace product literature describes a 36-needle configuration with insulated and non-insulated options. impactaesthetics.com
The number 36 identifies the needle count. It does not identify insulation type, supported device generation or packaging quantity.
Two cartridges described as 36-pin products can still differ in construction and compatibility. Do not assume that every 36-pin RF cartridge is suitable for Vivace equipment.
| Specification | What it identifies |
|---|---|
| 36 pin | Needle count |
| Insulated | Needle insulation design |
| Non-insulated | A different needle construction |
| Cartridge reference | Exact product identity |
| Pack quantity | Number of cartridges supplied |
| Device compatibility | Supported console and handpiece |
Insulated vs Non-Insulated Vivace Tips
The main difference concerns the conductive region of the needle.
In an insulated design, an insulating coating covers part of the needle shaft, leaving a designated section exposed. In a non-insulated design, the shaft is not covered by that insulating coating.
Vivace literature describes insulated needles as delivering RF through the exposed end section, while non-insulated needles deliver through the conductive needle length. The exact product specification should be confirmed from the applicable documentation. dar-pharma.com
Vivace Insulated Tips
When purchasing insulated cartridges, confirm that the label and documentation explicitly identify the product as insulated.
Do not rely on a seller’s photograph or a shortened name such as “blue tip.” Ask for the complete reference, supported equipment and manufacturer identity.
Insulation does not, by itself, establish guaranteed safety, comfort or results. Clinical suitability depends on the complete system, operating instructions and professional assessment.
Vivace Non-Insulated Tips
Non-insulated cartridges are a separate purchasing item and should be tracked separately in inventory.
A quotation should state “non-insulated” clearly. If the product title, package photograph and written description disagree, resolve the discrepancy before payment.
Do not substitute non-insulated cartridges for insulated ones solely because they are available or less expensive.
Blue Tips, Red Tips and LED Modes
Customers may encounter blue or red cartridge descriptions in supplier listings. However, color terminology requires clarification.
There are three different things a color may describe:
- Cartridge housing.
- Packaging or label.
- LED illumination mode.
SHENB’s page confirms selectable red and blue LEDs. That does not establish a universal color code for cartridge insulation. shenb.com
When ordering “Vivace blue tips” or “Vivace red tips,” request written confirmation of the needle type. The insulation description should remain part of the quotation and invoice.
Needle Depth Is Different From Needle Count
SHENB describes the referenced Vivace system as having an adjustable depth range of 0.5–3.5 mm in 0.1 mm increments. shenb.com
That system specification is different from the cartridge’s 36-pin count. It also does not establish a recommended treatment depth for an individual patient.
Keep these details separate:
- Needle count.
- Insulation design.
- Supported depth range.
- RF frequency options.
- Cartridge compatibility.
- Clinical operating parameters.
A product listing should not use one specification as a substitute for another.
Vivace, Vivace Ultra and Other RF Systems
Similar names or a shared manufacturer do not establish cartridge interchangeability.
Before purchasing a cartridge for Vivace, identify the exact console and handpiece. Do not assume that a product listed for Vivace Ultra, UltraVision, VirtueRF or another RF system fits the Vivace equipment in your clinic.
A matching needle count or similar connector is not sufficient proof.
Provide the supplier with the equipment label and reference of the currently verified cartridge. Where uncertainty remains, obtain confirmation from the manufacturer or equipment provider.
Original and Third-Party Vivace Cartridges
Product origin and compatibility are separate questions.
A seller describing a cartridge as “compatible with Vivace” has not established that SHENB manufactured it. Conversely, an independent seller may offer manufacturer-original goods, but the origin claim still requires verification.
Ask:
- Who manufactured the cartridge?
- What supports an original-product claim?
- Which equipment does it support?
- What documentation establishes compatibility?
- Is the seller authorized or independent?
- What warranty or seller support applies?
Packaging photographs assist identification but are not conclusive proof of authenticity.
Packaging, Expiry and Single Use
Check the instructions and labeling applicable to the supplied cartridge.
Before use, confirm the model, insulation type, expiry information and protective package condition. Keep items with uncertain identity or damaged protective packaging separate from usable stock.
Single-use cartridges should not be cleaned for reuse or shared between patients. Follow the applicable instructions for handling and disposal.
A cartridge’s appearance after a procedure does not establish suitability for another use.
What If a Cartridge Does Not Fit or Operate?
Stop and follow the equipment’s troubleshooting instructions.
Do not force the cartridge into the handpiece, modify the connector or bypass a warning. An operational problem may require assessment of the cartridge, connection, handpiece or system.
Record the exact model, batch information, equipment identification and error message. Supply relevant photographs or video without patient-identifying information.
Persistent problems should be assessed by the manufacturer or a qualified service provider.
Frequently Asked Questions
Are Vivace tips and cartridges the same thing?
Suppliers commonly use both terms for the replaceable needle consumable. Confirm the exact reference and insulation type.
Does 36 pin mean insulated?
No. Needle count and insulation are separate specifications.
Are blue cartridges always insulated?
Do not assume a universal color code. Confirm the printed product description.
Does blue LED mean the cartridge is insulated?
No. LED mode and needle construction are different features.
Can any 36-pin RF cartridge replace a Vivace tip?
No compatibility should be assumed from needle count alone.
Are Vivace and Vivace Ultra cartridges interchangeable?
Confirm the exact supported equipment combination rather than relying on similar names.
How many cartridges come in a box?
Pack quantities vary by offer. Confirm both boxes and total individual cartridges.
Where can I compare purchasing options?
Read our [Vivace cartridge buying guide: prices, pack quantities and supplier checks](/blogs/news/buy-vivace-rf-tips-cartridges-price-guide).
Identify the Complete Cartridge
A complete Vivace RF tip description includes needle count, insulation type, exact reference and supported equipment. Confirm those details before comparing prices or placing an order.